1.Incazelo
I-Thermometer Ye-Infrared Yomzimba Engathinteki Iklanyelwe Ngokukhethekile ukuthatha izinga lokushisa lomzimba womuntu kungakhathaliseki izinga lokushisa legumbi
Kuya ngezinhlobo ezahlukene zesikhumba nokuqina, kungase kube nomehluko wokushisa Lapho izinga lokushisa langaphakathi liwumehluko omkhulu, izinga lokushisa lomzimba we-infrared kufanele libekwe kulelo gumbi imizuzu eyi-15 kuya kwengama-20 ngaphambi kokulisebenzisa.
2.Ulwazi Lokuphepha
•Lolu cingo kufanele lusetshenziselwe kuphela izinhloso ezichazwe kule ncwadi yeziqondiso.
•Le divayisi kufanele isetshenziswe kuphela ebangeni lokushisa eliphakathi kuka-10°C no-40°C.
•Ungayibeki lesi thermometer ezimweni zokushisa ezeqisayo ezingu>40 C noma<0 C.
•Ungalivezi le thermometer kuma-shock kagesi
•Ungalusebenzisi ucingo kumswakama ohlobene ongaphezu kuka-85%RH
•Ungalusebenzisi ucingo eduze nezinkundla ezinkulu zikamagnetic ezifana nezingenazintambo noma omakhalekhukhwini.
•Gcina idivayisi ikude namanzi nokushisa, okuhlanganisa ukukhanya kwelanga
•Ungaluwisi noma ulungqongqoze ucingo, futhi ungalusebenzisi uma lonakele
•Kungase kuthinte ukunemba kwezilinganiso lapho isiphongo simbozwe umjuluko wezinwele, ikepisi noma isikhafu.
•Gcina ibanga lokulinganisa lingu-<5cm(<2in)
•Lapho ithemometha ye-infrared yomzimba kufanele ishiywe kulelo gumbi phakathi nemizuzu eyi-15 kuya kwengama-20 ngaphambi kokuyisebenzisa.
•Kungase kuthinte ukunemba kwezilinganiso lapho isiphongo sigcwele umjuluko
noma ezinye izici, sicela uthathe izinga lokushisa ngemuva kwe-ear lobe.
•Hlanza ingilazi nge-cotton bud oswakanyiswe kancane ngotshwala obungama-70%.
3.Izici
•Izilinganiso ezinembile zokungeyena othintana naye
•Isikhombi selaser esakhelwe ngaphakathi
•Umsebenzisi angakhetheka u-°C noma u-°F(Ukhiye othi “MO DE” cindezela isikhathi eside mroe kunemizuzwana engu-5)
•Ibanga lokukhetha elizenzakalelayo kanye Nokulungiswa Kokubonisa 0.1°C(32.1°F)
•Bamba Idatha Okuzenzakalelayo & Ukucisha Ngokuzenzakalelayo
•Setha inani le-alamu(inani elizenzakalelayo le-alamu lingu-38°C(100.°F)
Umyalelo: vula iyunithi bese ucindezelainkinobho yeMODEH imizuzwana emi-3, isibonisi se-LCD”Fl
Cindezela kabusha u-"MODE" ukuze ufake u-38°C(ukusetha i-alamu ye-dufaIt), ukhuphule noma wehlise inani
Ngokucindezela umcibisholo oya phezulu noma phansi, cindezela isikhali sokulinganisa ukuze uqedele ukusetha.
•Ukukhethwa kwe-buzze
Isiyalezo: vula iyunithi bese ucindezela inkinobho ethi “MODE” imizuzwana emi-3, isibonisi se-LCD”F3
Cindezela kabusha” MODEH ukuze uhlele, cindezela umcibisholo oya phezulu noma phansi ukuze ukhethe,, VULA” noma,, VALIWE”.cindezela isibali sokulinganisa ukuze uqedele ukusetha
•Ukukhetha izinga lokushisa lomzimba noma le-ambient
Indlela Yokusebenza: Kokubekwe eceleni, Cindezela inkinobho ye-” Mode, bese isikrini se-LCD sibonisa”Fl 38.0°C,r, ngokucindezela i-”"ukushintsha Idatha, Ngena kusilungiselelo se-F2 ngokucindezela i-MODE" isikhathi esengeziwe, bese isikrini se-LCD sibonisa "F2 0.0 ° C", ungacindezela, ku-A" ukuze ushintshe Idatha, Kuyindlela efanayo yokusebenza ye-F3 kanye F4 Qaphela: “5URF”Ngokukhombisa into, “Umzimba we-brow mode yomuntu ngaphansi kwesethingi F4
4. Ukusetshenziswa Okuhlosiwe
•I-Non-contact Body Infrared Thermometer yakhelwe ukulinganisa izinga lokushisa lesiphongo sezingane ezisanda kuzalwa kanye nabantu abadala ngaphandle kokuxhumana nomzimba womuntu.Ingasetshenziswa abathengi endaweni yasekhaya ngokuhambisana ne-ASTM 1965-1988
•Izincazelo ezijwayelekile ze-Infrared Thermometers for Intermittent Determination of Patient Temperature
5.Isixwayiso Ngaphambi Kokusetshenziswa
•Ukuze uthole imiphumela enokwethenjelwa nezinzile, lapho ushintsha indawo ezungezile uyisa egumbini elinomehluko omkhulu wokushisa, kunconywa ukuthi ushiye I-Thermometer Yomfana Ongaxhumani Ne-infrared kuleli zinga lokushisa elizungezile imizuzu eyi-15 ukuya kwangu-20 ngaphambi kokuyisebenzisa.
•Ngokuya ngezinhlobo ezahlukene zesikhumba nokuqina, kungase kube nomehluko wokushisa.
•Ungayibeki ithermometer elangeni noma emanzini.
Vumela isikhawu esiyiminithi elilodwa phakathi kokulinganisa okubili.
Amazinga Okushisa Avamile Ngokwendlela Yokulinganisa
Isilinganiso | Indlela Yezinga lokushisa °C | Izinga lokushisa Elijwayelekile |
I-Rectal | 36.6 kuya ku-38 | 97.8 ukuze 100.4 |
Ezomlomo | 35.5 kuya ku-37.5 | 95.9 kuya ku-99.5 |
Umsizi | 34.7 kuya ku-37.3 | 94.4 kuya ku-99.1 |
I-Aurilar | 35.8 kuya ku-38 | 96.4 ukuze 100.4 |
Okwesikhashana(Thermo Flash) | 35.8 kuya ku-37.8 | 96.4 ukuze 100.0 |
Ubudala | Izinga lokushisa °C | I-Temp°F |
Iminyaka engu-0-2 | 34.6 kuya ku-38 | 97.8 ukuze 100.4 |
Iminyaka engu-3-10 | 36.1 kuya ku-37.8 | 97.0 ukuze 100.0 |
Iminyaka engu-11-65 | 35.9 kuya ku-37.6 | 96.6 kuya ku-99.7 |
> iminyaka engu-65 | 35.8 kuya ku-37.5 | 96.4 ukuze 99.5 |
7. Imininingwane Yezobuchwepheshe
Izimo Ezivamile Zokusebenzisa:
Bonisa Ukulungiswa | 0.1oC(32.1oF) |
Izinga Lokushisa Lokusebenza | 10to40°C(50tol04.°F) |
Izinga Lomswakama | ≤85% |
Amandla | R03AAA1.5V2 |
Usayizi | 95×42.5xl56mm(LXWXH) |
Isisindo | awu 124g |
Ibanga lokulinganisa:
Ibanga Lokulinganisa Lomzimba | 32.0to43.0°C(90tol09.4°F) |
Ibanga Lokulinganisa Le-Ambient | I-Oto 60°C(32tol40°F) |
Ukunemba Komzimba | ±0.3°C(32.54°F) |
Ukunemba kwe-Ambient | ±1°C(33.8°F) |
Ukulinganisa Ibanga | <5cm (2 in) |
Misa Okuzenzakalelayo | 7 isekhondi |
Ukunemba kwe-Thermometer ye-Infrared Yomzimba:
32to35.9°C/93.2to96.6°F | ±0.3°C/32.9°F | Ngokusho kwe-ASTMSstandard E1965-1998(2003) |
36 kuya ku-39°C/96.8kuya ku-102.2°F | ±0.2°C/32.36°F | |
39 kuya ku-42.5/102.2 kuya ku-108.5°F | ±0.3°C/32.9°F |